Effective frustraton of heat with zero consumption

It is often called the cooler with zero consumption, which we can daringly call a dream of every company power engineer.

Has it also ever crossed your mind that you have such processes in your operation where you frustrate heat in such way that for frustration you still need another energy, i.e. electric energy? Actually, it does not make much sense as two energies meet in one equipment that are not used further in any way, but they actually disappear and the operator reimburses high costs of the operation of such coolers. Our solution is the cooling with zero own consumption of electricity.

They are classic heat exchangers when the technology requires for its operation to frustrate a certain amount of heat in these air exchangers. Classic installations are such that for heat frustration they use fans with high own consumption of electric energy for feeding fans. Thereby the circuit is cooled down by the given delta t. The principle of our coolers is the same, only with that difference that we use the input energy of heat just for the production of electric energy feeding fans of the cooler. Not by kilowatt of energy more, not less.

Investment in the refrigeration circuit is not only non-returnable investment, but some other operating costs are necessary just for covering the own consumption of such coolers. However, if cooling has no consumption, then this investment can be economically returnable, which has seemed impossible so far.
 

Let us propose by us our cooler with zero consumption
or an active cooler with additional power generation.
Savings implementation is clear and legible for you here.

 

For more information, please
contact us


Mgr. Pavel Žwak
Email:
pavel.zwak@bpower.cz
Phone: 
+420 725 902 003

Technology ORCAN cooler

The ORCAN technologies focus on a wide range of the ORC systems, from the smallest ones (5 kW) up to bigger ORC systems producing 300 kW of electricity. Another flagship of this company includes zero energy consumption coolers - ORCAN cooler

Tens of installations of these units all over Europe are evidence of first-rate quality of German technology. The supplier of expanders for ORC is the company Bitzer – the world number one in the field of producers of compressors.

 

 

ORCAN cooler – the cooler of the new generation with zero electric energy consumption:

The built-in ORC module (Organic-Rankin-Cycle) converts waste heat into electricity that is used for the cooling system operation. In the engine of the output of 500 kW it can save up to 8 kW/h.

 

ORCAN cooler solves the following problems with the cooling of cogeneration units:

  • The fact that the current cooling is undersized forces to limit the output in the summer months = loss of sales
     
  • Older coolers lose their cooling effectiveness and are often liable to failure = increased operating costs
     
  • Due to the engine overheating, oil is often exchanged = increased service costs

 


The cooler is delivered in the horizontal version in the three basic series – 400 kWth, 600 kWth and 800 kWth. When the so-called double cooler is selected, both engine circuits (LT and HT) are cooled down simultaneously.

  • Suitable for input temperature in the cooler from 60˚C
  • Waste heat with output more than 125 kWth
  • At ambient temperatures up to 30˚ C with the minimal/zero electricity consumption
  • It is not a source of the production of electric energy
  • Fast return on investment
     

ORCAN cooler has the best output-price ratio in comparison with the standard coolers:

Low-cost cooler Effective cooler ORCAN cooler
Low CAPEX *** ** **
Low OPEX * ** ***
Total costs * ** ***

 

 


Technology ElectraTherm Active Cooler

Active Cooler AC800
 

It is a technology for efficient cooling of waste heat not only with zero electricity consumption, but also with further electricity production. This is done using the ORC system integrated in the heatsink. The ORC unit produces electricity from waste heat. It is used for its own cooling consumption of the Active Cooler.

Electricity forms in addition to own consumption so it can be further processed into the distribution system. Active Cooler is not only a full-fledged cooler of excess energy, but also another new source of electricity.

For more information, please
contact us


Lubomír Sovíček
Email: lubomir.sovicek@bpower.cz
Phone: +420 734 576 035